Paviath Integrated Solution Paviath

Qualification seismic resistance of the heat exchanger cooling the cooling pond

 
The computational model
 
The computational model
 
The computational model of the heat exchanger with loads
 
The scheme of installation of support in the calculation model

The calculation results

 
The frequency of 1.589 Hz. first mode
 
The frequency of 5.456 Hz. The third form
 
The frequency of 9,207 Hz. The fifth form
 
The frequency of 12,371 Hz. sixth form
 
The stress distribution in the heat exchanger at Nue + MDE
 
The stress distribution in the body shell at Nue + MDE
 
The stress distribution in the support at Nue + MDE
 
The stress distribution in the elliptic bottom at Nue + MDE
 
The stress distribution in the pipe when Æ628 Nue + MDE
 
The stress distribution in the pipe when Æ325 Nue + MDE
 
The stress distribution in the flange at Nue + MDE
 
The stress distribution in the tubesheet at Nue + MDE
 
 
 
 
 
 