Qualification pump earthquake resistance dampening storage pool

 
Estimated pump model
 
The geometry of the pump

The calculation results

 
The frequency of 186,961 Hz. first mode
 
The frequency of 209,393 Hz. The second form
 
The frequency of 308,818 Hz. The third form
 
The frequency of 940,733 Hz. The 10th form

Proper pump oscillations form

 
The stress distribution in the pump when Nue + PP
 
The stress distribution in the pump cover when Nue + PP
 
The stress distribution in the pump housing when Nue + PP
 
The stress distribution in the pump housing when Nue + PP
 
 
 
 
 
 