PAVIATH INTEGRATED SOLUTION
PAVIATH INTEGRATED SOLUTION
Paviath

Qualification seismic resistance of the heat exchanger cooling the cooling pond

The computational model
The computational model
The computational model of the heat exchanger with loads
The scheme of installation of support in the calculation model

The calculation results

The frequency of 1.589 Hz. first mode
The frequency of 5.456 Hz. The third form
The frequency of 9,207 Hz. The fifth form
The frequency of 12,371 Hz. sixth form
The stress distribution in the heat exchanger at Nue + MDE
The stress distribution in the body shell at Nue + MDE
The stress distribution in the support at Nue + MDE
The stress distribution in the elliptic bottom at Nue + MDE
The stress distribution in the pipe when Æ628 Nue + MDE
The stress distribution in the pipe when Æ325 Nue + MDE
The stress distribution in the flange at Nue + MDE
The stress distribution in the tubesheet at Nue + MDE
info@paviathintegratedsolution.com www.paviathintegratedsolution.com