PAVIATH INTEGRATED SOLUTION
PAVIATH INTEGRATED SOLUTION
Paviath

Qualification earthquake resistance of pipelines purge-loading system, including SRC seal assembly and filling CGU ECCS

Process piping diagram
Executive pipeline circuit
The geometry of the pipeline
Finite element model of the pipeline

The calculation results

The frequency of 2.128 Hz. first mode
The frequency of 2.474 Hz. The second form
The frequency of 3.964 Hz. tenth form
The frequency of 5.356 Hz. Twentieth form
``
The distribution of total displacement in the pipe during seismic actions
info@paviathintegratedsolution.com www.paviathintegratedsolution.com